|  | Product Details: 
 Payment & Shipping Terms: 
 | 
| Product Name: | ISO75-1 ISO306 HDT VICAT Softening Point Test Apparatus For Thermoplastic Materials With Four Frame | Test Standards: | ISO75-1, ISO306, GB/T8802, GB/T1633, GB/T1634, ASTM D 1525-1991, ASTM D648-06 | 
|---|---|---|---|
| Test Frame Lifting Mode: | Auto | Deformation Measurement Range: | -1.00~10.00mm | 
| Test Stations: | 4 | Maximum Deformation Measurement Error: | 0.01mm | 
| Heating Rate: | 50℃/h,120℃/h | Current Source: | 4KW, 220VAC, 50HZ | 
| Highlight: | Thermoplastic HDT and Vicat testing instruments,HDT VICAT Softening Point Test Apparatus,Four Frame HDT / VICAT Testing Machine | ||
The ISO75-1/ISO306 four-frame HDT/VICAT softening point tester determines thermal deformation temperature of thermoplastics. This precision instrument is widely used in plastic raw material production, R&D, and educational applications.
| Attribute | Value | 
|---|---|
| Product Name | ISO75-1 ISO306 HDT VICAT softening point test apparatus for thermoplastic materials with four frame | 
| Test Standards | ISO75-1, ISO306, GB/T8802, GB/T1633, GB/T1634, ASTM D 1525-1991, ASTM D648-06 | 
| Test Frame Lifting Mode | Auto | 
| Deformation Measurement Range | -1.00~10.00mm | 
| Test Stations | 4 | 
| Maximum Deformation Measurement Error | 0.01mm | 
| Heating Rate | 50℃/h,120℃/h | 
| Current Source | 4KW, 220VAC, 50HZ | 
| Parameter | Value | 
|---|---|
| Model | XRW-300BT-Ⅳ | 
| Temperature control range | Room temperature ~300℃ | 
| Maximum temperature error | ±0.5℃ | 
| Heating rate | 50℃/h,120℃/h, or set between 50-120℃/h | 
| Temperature measurement point | 1 | 
| Test frame number | 4 | 
| Test frame lifting mode | Auto | 
| Range of deformation measurement | -0.1~10mm | 
| Maximum deformation error | ±0.005mm | 
| Deformation resolution | 0.001mm | 
| Sample supports span | 64mm,100mm | 
| Load bar and press (needle) weight | 74g | 
| Voltage and power | 220V, 4KW | 
| Thermal expansion coefficient of sample itself | <0.005/100℃ | 
| Working medium | Methylsilicone oil or transformer oil | 
| Cooling-down method | Natural cooling above 150℃, water cooling below 150℃ or natural cooling | 
Our comprehensive support package includes:
The HDT VICAT Testing Machine is securely packed in robust wooden crates with foam padding to prevent transport damage. We partner with reliable carriers to ensure timely delivery worldwide.
XRW-300F
ISO9001 certified
1 set
$2400 to $6000 USD
10 to 15 working days
 
  
  
 
Contact Person: Ms. Zoe Bao
Tel: +86 13311261667