Product Details:
Payment & Shipping Terms:
|
| Product Name: | Accurate And Professional HDT VICAT Tester For High-Performance Material Analysis | Product Category: | HDT VICAT Testing Machine |
|---|---|---|---|
| Test Standards: | ISO75-1, ISO306, GB/T8802, GB/T1633, GB/T1634, ASTM D 1525-1991, ASTM D648-06 | Heating Medium: | Silicone Oils, Glycerine, Ethylene Glycol, Mineral Oil |
| Current Source: | 4KW, 220VAC, 50HZ | Deformation Measurement Range: | -1.00~10.00mm |
| Test Stations: | 3 | Maximum Deformation Measurement Error: | 0.01mm |
| Highlight: | HDT VICAT Tester for material analysis,Professional HDT VICAT Tester,Accurate VICAT Tester for high-performance materials |
||
This HDT Vicat Testing Machine is strictly compliant with multiple international and national test standards, including ISO 75-1, ISO 306, GB/T 8802, GB/T 1633, GB/T 1634, ASTM D1525-1991, and ASTM D648-06. Such comprehensive standard compliance ensures its broad applicability across various industries and application scenarios.
As a member of the Vicat Heat Deflection Temperature Tester series, this machine is specifically designed for testing the thermal performance of thermoplastic materials. It is capable of measuring the heat deflection temperature (HDT) of plastics under load, and is widely applied in the plastics industry for quality control (QC), product research & development (R&D), and performance verification.
In summary, the HDT Vicat Testing Machine is a highly reliable and versatile testing instrument suitable for a wide range of industries and applications. Its compliance with multiple authoritative standards, precise deformation measurement range, and multi-station design make it an indispensable tool for laboratories, production facilities, and quality inspection departments engaged in thermoplastic material processing, research, and quality control.
ISO75-1, ISO306, GB/T8802, GB/T1633, GB/T1634, ASTM D 1525-1991, ASTM D648-06
| Product Name | Determination Of Vicat Softening Temperature Of Plastic Rate A 50℃/h Rate B 120℃/h |
|---|---|
| Equipment Type | Vicat Heat Deflection Temperature Tester, Vicat Temperature Softening Test Apparatus, Vicat Thermoplasticity Testing Device |
| Loading | 10±0.2N, 50±1.0N |
| Deformation Measurement Range | -1.00~10.00mm |
| Heating Rate | 120℃/h, 50℃/h |
| Maximum Deformation Measurement Error | 0.01mm |
| Span Of Sample Supports | 64mm, 100mm |
| Temperature Control Range | Room temperature ~300℃ |
| Equipment Size | 700mm×480mm×750mm |
| Test Stations | 3 |
| Maximum Temperature Error | ±0.5℃ |
The HDT VICAT Testing Machine is a high-precision instrument specifically designed for determining the deflection temperature under load and softening point of thermoplastic materials--critical for evaluating thermal performance in polymer quality control and R&D.
To ensure the stable operation and optimal performance of your HDT VICAT Testing Machine, our technical support and service portfolio includes the following professional offerings:
We are dedicated to delivering industry-leading technical support and services for the HDT VICAT Testing Machine, committed to meeting our customers' needs throughout the entire equipment lifecycle.
Contact Person: Ms. Zoe Bao