logo
Home ProductsDifferential Scanning Calorimeter

Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement

Customer Reviews
Thanks for your help for Hydrostatic pressure testing machine products

—— Grupo Latyn

It has been a pleasure working with you, and I greatly appreciate the effort you’ve put collaborations between our companies.

—— Petra Plastic Industries LLC

I'm Online Chat Now

Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement

Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement

Large Image :  Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement

Product Details:
Place of Origin: BEIJING, CHINA
Brand Name: TH
Certification: ISO9001 CE
Model Number: DSC-ZS5
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Packaging Details: Standard export wooden box
Delivery Time: 10~15 work days
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability: 20 sets per month
Detailed Product Description
Product Name: Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface For Accurate Polymer Oxidation Induction Period Measurement Temperature Resolution: 0.01 ℃
Heating Rate: 0.1~40℃/min Cooling Rate: 0.1~20℃/min
DSC Range: 0 ~ + 500 Mw DSC Resolution: 0.01 MW
DSC Sensitivity: 0.01 MW Temperature Control Mode: Heating, Cooling, Constant Temperature
Highlight:

Industrial differential scanning calorimeter with touch interface

,

Polymer oxidation induction period calorimeter

,

Widescreen DSC for accurate measurements

Industrial Differential Scanning Calorimeter with Widescreen Touch Interface
This Differential Scanning Calorimeter (DSC) features a touchscreen interface specifically engineered for oxidation induction period (OIT) testing of polymeric materials. It supports one-key operation and full software automation, streamlining testing workflows and ensuring consistent, error-free operation.
Standards Compliance
This instrument fully complies with the following international and national standards:
  • GB/T 19466.2-2009 / ISO 11357-2:1999
  • GB/T 19466.3-2009 / ISO 11357-3:1999
  • GB/T 19466.6-2009 / ISO 11357-6:1999
Key Features
  • Industrial-Grade Widescreen Touch Interface: Information-rich display showing comprehensive real-time data including set temperature, sample temperature, gas flow rates, differential thermal signal, and switch statuses
  • Universal USB Communication Interface: High universality with reliable data transmission and built-in self-recovering connection functionality
  • Compact Furnace with Adjustable Thermal Rates: Supports stepless adjustment of heating and cooling rates for various polymeric material OIT tests
  • Optimized Installation & Anti-Contamination Design: Mechanical fastening method eliminates contamination of differential thermal signal
  • Efficient Heating & Cooling System: Electric heating with circulating cooling water, compact structure with small footprint
  • High-Precision Temperature Control: Dual temperature probes and specialized control technology for excellent repeatability
  • Automatic Gas Channel Switching: Fast switching between two gas channels with short stabilization time
  • Standard Reference Samples: Includes calibration materials for temperature and enthalpy coefficients
  • Versatile Software Compatibility: Supports all screen resolutions and multiple Windows operating systems
  • Customizable Automated Operation: Supports user-edited device operation modes with dozens of configurable instructions
  • Fully Enclosed Protective Structure: Prevents foreign object entry, avoids furnace contamination, and reduces maintenance
Technical Specifications
Temperature Range 0℃ ~ 500℃
Temperature Resolution 0.01℃
Heating Rate 0.1 ~ 40℃/min
Cooling Rate 0.1 ~ 20℃/min
Calorimetric Resolution 100%
Constant Temperature Range 5℃ ~ 500℃
Temperature Control Modes Heating, cooling, constant temperature
DSC Range 0 ~ ±500mW
DSC Resolution 0.01mW
DSC Sensitivity 0.01mW
Working Power AC 220V 50Hz 300W or other
Atmosphere Control Two-channel automatic control (nitrogen and oxygen)
Gas Flow Range 0-200mL/min
Gas Pressure 0.2MPa
Gas Flow Accuracy 0.2mL/min
Crucible Type Aluminium crucible Φ6.6×3mm (Diameter × Height)
Calibration Standard Includes standard materials (indium, tin, zinc)
Data Interface Standard USB interface
Display Mode 7-inch touch screen
Output Mode Computer and printer
Standard Configuration
DSC Machine 1 set
Aluminium Crucibles 300 pieces
Power Cords and USB Cable Each one
CD (Software & Operations Video) One
Soft-key One
Oxygen and Nitrogen Airways Each 5m
Operation Manual One
Standard Samples (Indium, Tin, Zinc) Each one
Tweezer and Medicine Spoon Each one
Custom Pressure Reducing Valve Joint and Quick Joint Two
Fused Glass Fuses Four
External Circulation Thermostat Sink One
Water Pipe One
Furnace Bracket
Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement 0
Software Interface
Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement 1 Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement 2 Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement 3 Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement 4

Contact Details
Beijing Tonghe Testing Machine Co., ltd

Contact Person: Ms. Zoe Bao

Tel: +86 13311261667

Send your inquiry directly to us (0 / 3000)