logo
Home ProductsHDT VICAT Tester

HDT Vicat Tester, Heat Deflection & Vicat Softening Point Instrument with Real-Time Monitoring and Auto Heating Stop for Plastic Material Testing

Customer Reviews
Thanks for your help for Hydrostatic pressure testing machine products

—— Grupo Latyn

It has been a pleasure working with you, and I greatly appreciate the effort you’ve put collaborations between our companies.

—— Petra Plastic Industries LLC

I'm Online Chat Now

HDT Vicat Tester, Heat Deflection & Vicat Softening Point Instrument with Real-Time Monitoring and Auto Heating Stop for Plastic Material Testing

HDT Vicat Tester, Heat Deflection & Vicat Softening Point Instrument with Real-Time Monitoring and Auto Heating Stop for Plastic Material Testing

Large Image :  HDT Vicat Tester, Heat Deflection & Vicat Softening Point Instrument with Real-Time Monitoring and Auto Heating Stop for Plastic Material Testing

Product Details:
Place of Origin: BEIJING, CHINA
Brand Name: TH
Certification: ISO9001, CE
Model Number: XRW-300C
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Packaging Details: Standard export wooden cases
Delivery Time: 10~15 work days
Payment Terms: T/T,L/C,D/A,D/P
Supply Ability: 15 sets per month
Detailed Product Description
Product Name: HDT Vicat Tester, Heat Deflection & Vicat Softening Point Instrument With Real-Time Monitoring And Auto Heating Stop For Plastic Material Testing Controll: By Computer
Test Station Moving Method: Automatic Mainframe Type: Vertical Type
Vicat Load: 10N ± 0.2 N , 50N ± 1N Max. Deformation Deviation: 0.001mm
Deformation Measuring Rage: 0 ~ 2.5mm Sample Frame Number: 3-6 Stations Can Be Selected
Highlight:

HDT Vicat tester for plastic materials

,

Vicat softening point instrument with auto heating stop

,

Heat deflection tester with real-time monitoring

HDT Vicat Tester - Heat Deflection & Vicat Softening Point Instrument
This advanced Thermal Deformation & Vicat Softening Point Tester features PLC programmable temperature control with computer display operation. Designed for exceptional accuracy and stable performance, the system provides real-time monitoring of test temperature and deformation values throughout the testing cycle. Automatic heating termination and comprehensive test reporting with graphical curve output make this instrument essential for quality control in inspection authorities, academic institutions, and manufacturing enterprises.
Test Method Definitions
Thermal Deformation Temperature Test: Determines the temperature at which a standard specimen deflects by a specified amount under bending load, achieving designated nominal surface stress in compliance with international standards. This method is crucial for plastic quality control and material R&D.
Vicat Softening Point Temperature Test: Measures the temperature at which a standard indenter penetrates 1 mm into the specimen surface under defined loading. Used to differentiate softening characteristics across various thermoplastic materials.
Key Features
  • Specimen frame lifting mechanism for easy sample handling
  • Measures thermal deformation and Vicat softening point temperatures
  • Compatible with non-metallic materials including plastics, rubber, nylon, and electrical insulation materials
  • Real-time temperature and deformation monitoring
  • Automatic heating termination upon test completion
  • Test report and graphical curve output capabilities
Compliance Standards
This testing instrument complies with comprehensive domestic and international standards including GB/T1633, GB/T1634, ISO75, ISO306, ASTM D648, ASTM D1525, and ISO 2507. Conformity ensures traceability and credibility of test results, meeting thermal performance evaluation requirements for laboratories, manufacturing facilities, and certification organizations.
Technical Specifications - Model XRW-300F
Parameter Specification
Testing Stations 3 stations (simultaneous testing of 3 samples)
Automation Automatic sample movement capability
Cooling System Air cooling above 150°C, water or natural cooling below 150°C
Deformation Measurement High precision digital display dial gauge
Heating Rates 50°C/h, 120°C/h
Maximum Temperature Deviation ±0.5°C
Deformation Deviation 0.01mm
Vicat Loads 10N ± 0.2N, 50N ± 1N
Fiber Stress 0.455 MPa and 1.82 MPa
Temperature Control Range Room temperature ~ 300°C
Deformation Measuring Range 0 ~ 10mm
Sample Frame Number 3
Test Span 60~120mm
Heating Power 6KW
Power Supply 220V 50Hz
Display Color touch screen
Type and Display Vertical type using computer control system
Standard Configuration
  • Main frame: 1 set
  • Electric cabinet: 1 set
  • Specimen holder: 3 sets
  • Vicat indenter: 3 sets
  • Heat deflection indenter: 3 sets
  • Displacement sensor: 3 sets
  • Power line: 2 sets
  • Connecting line: 2 sets
  • Operation manual: 1 set
  • Certificate: 1 set
  • Packing list: 1 set
Product Images
HDT Vicat Tester front view showing control panel and testing stations Close-up view of specimen holders and measurement components Side view of HDT Vicat testing instrument with detailed labeling Operation interface display showing real-time monitoring data

Contact Details
Beijing Tonghe Testing Machine Co., ltd

Contact Person: Ms. Zoe Bao

Tel: +86 13311261667

Send your inquiry directly to us (0 / 3000)

Other Products